In order to better meet users' need, our CDCP study questions have set up a complete set of service system, so that users can enjoy our professional one-stop service. We not only in the pre-sale for users provide free demo, when buy the user can choose in we provide in the three versions, at the same time, our CDCP Training Materials also provides 24-hour after-sales service. Such a perfect one-stop service of our CDCP test guide, believe you will not regret your choice, and can better use your time, full study, efficient pass the CDCP exam.
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
| Topic 6 |
|
| Topic 7 |
|
| Topic 8 |
|
| Topic 9 |
|
| Topic 10 |
|
We know that tenet from the bottom of our heart, so all parts of service are made due to your interests. You are entitled to have full money back if you fail the exam even after getting our CDCP test prep. Our staff will help you with genial attitude. We esteem your variant choices so all these versions of CDCP Study Materials are made for your individual preference and inclination.
NEW QUESTION # 40
What is the most preferred unit of measure for cooling capacity?
Answer: B
Explanation:
Cooling capacity is the measure of a cooling system's ability to remove heat from a space. The most preferred unit of measure for cooling capacity is watt (W), which is the SI unit for power. Watt is defined as the amount of energy transferred or converted per unit time. One watt is equal to one joule of energy per second. Using watt as the unit of measure for cooling capacity allows for easy comparison and calculation of the cooling performance and efficiency of different cooling systems.
Other units of measure for cooling capacity are ton, BTU, and horsepower, but they are less common and less convenient than watt. Ton is a unit of measure that describes how much water at freezing temperature can be frozen in 24 hours, equivalent to 3.5 kW or 12,000 BTU/h. BTU (British Thermal Unit) is a unit of measure that describes the amount of heat required to raise the temperature of one pound of water by one degree Fahrenheit, equivalent to 0.293 W. Horsepower is a unit of measure that describes the rate at which work is done, equivalent to 746 W.
References:
*Data Centre Professional (CDCP) Reference Materials, page 8, section 2.1.1
*Data Centre Professional (CDCP) Preparation Guide, page 11, section 2.1.1
*Cooling capacity - Wikipedia
*Air Conditioner BTU Calculator
*Air conditioning 101: Basics, working principle and sizing ... - GlobalSpec
*How is cooling capacity measured? - Sage-Advices
*Everything You Need to Know About Cooling Capacity
NEW QUESTION # 41
The UPS vendor is offering the latest model of their UPS to you. The vendor indicates that the UPS is categorized as VFD class.
Is this UPS a fit for your mission-critical data centre?
Answer: C
Explanation:
A UPS (uninterruptible power supply) that is categorized as VFD class is not a fit for your mission-critical data centre, because it does not provide adequate protection against voltage and frequency variations. VFD stands for Voltage and Frequency Dependent, which means that the output voltage and frequency of the UPS depend on the input voltage and frequency. VFD UPSs are also known as offline, standby, or line-interactive UPSs. They typically switch to battery power only when the input power fails or goes beyond a certain threshold. However, this switching may cause a brief interruption or a transient in the output power, which can affect the performance and reliability of the ICT equipment. Moreover, VFD UPSs do not filter or regulate the input power, which means that they pass on any voltage or frequency fluctuations, harmonics, or noise to the output power. These power quality issues can also damage or degrade the ICT equipment and the data.
For your mission-critical data centre, you need a UPS that is categorized as VFI class, which stands for Voltage and Frequency Independent. VFI UPSs are also known as online, continuous, or double-conversion UPSs. They provide a constant and clean output power that is independent of the input power. VFI UPSs convert the input AC power to DC power, and then convert it back to AC power with the desired voltage and frequency. This double conversion process isolates the output power from the input power, and eliminates any power quality issues. VFI UPSs also have zero switching time, which means that they do not cause any interruption or transient in the output power when switching to battery power. VFI UPSs are designed to protect the ICT equipment and the data from any adverse effects of voltage and frequency variations, and to ensure the highest level of availability and reliability.
References:
1: CDCP Preparation Guide, page 17, section 2.3.1 2: Understanding UPS Classification: Fuji Electric's Technical Guide3, page 1, section 1 4: Uninterruptible Power Supplies Key Product Criteria5, page 1, section
1 6: UPS Function: Reduced Input Voltage for VFDs - KEB7, page 1, section 1
NEW QUESTION # 42
Which one of the following is an example of Indirect Cost?
Answer: B
Explanation:
Damaged brand perception is an example of an indirect cost because it is not directly related to a specific product or service, but rather to the overall reputation and image of the company. Damaged brand perception can result from various factors, such as poor quality, customer dissatisfaction, security breaches, or negative publicity. Damaged brandperception can affect the company's ability to attract and retain customers, partners, and investors, and thus reduce its profitability and competitiveness.
References: EPI Data Centre Training Framework, Indirect Cost: Definition and Example, What Is Indirect Cost? Definition, Types and Examples.
Learn more
1 indeed.com2 o
NEW QUESTION # 43
What type of heal does ICT equipment generate?
Answer: D
Explanation:
According to the Certified Data Centre Professional (CDCP) reference materials, ICT (Information and Communication Technology) equipment such as servers, switches, and storage devices generate sensible heat.
Sensible heat is the heat energy that causes a change in temperature of the air but does not contribute to humidity or moisture content. This is in contrast to latent heat, which involves a change in moisture (humidity) in the air, such as from evaporation or condensation.
ICT equipment does not introduce moisture into the environment; it only raises the temperature of the surrounding air, making it sensible heat. Proper data center cooling focuses on removing this sensible heat load to maintain optimal equipment operating conditions. Latent heat loads, such as those from people or water leaks, are typically not generated by ICT equipment and are managed differently in facility design.
Radiant heat is a minor consideration and typically refers to heat transferred by electromagnetic waves (e.g., from sunlight or hot surfaces), not the primary mode of heat transfer from ICT equipment, which is primarily through convection (airflow) and is measured as sensible heat.
:
EPI CDCP Exam Preparation Guide: https://www.epi-ap.com/uploads/file/exam%20prep
/english_preparation_guide_cdcp_202003.pdf
EPI Certified Data Centre Professional (CDCP) Course Content: https://www.epi-ap.com/services/1/3/4
/Certified_Data_Centre_Professional_(CDCP)
EPI Data Centre Framework: https://www.epi-ap.com/content/31/67/EPI_Data_Centre_Framework
NEW QUESTION # 44
Which one of the following represents the three elements (oxygen, heat and fuel) to interact in order for the fire to exist?
Answer: C
Explanation:
The fire triangle is a simple model that illustrates the three elements a fire needs to ignite: heat, fuel, and an oxidizing agent (usually oxygen). A fire naturally occurs when the elementsare present and combined in the right mixture. A fire can be prevented or extinguished by removing any one of the elements in the fire triangle.
References: EPI Data Centre Professional (CDCP®) Preparation Guide, page 9; Fire triangle - Wikipedia; The Fire Triangle Explained - Fire Action
NEW QUESTION # 45
......
Currently we release the latest CDCP reliable exam answers for the test which not only cover the accurate study guide but also include more than 80% questions and answers of the real test. If it is still difficult for you to pass exam, or if you are urgent to clear exam in a short at first attempt, our CDCP Reliable Exam Answers will be your only valid choice. Don't hesitate again. Our buyers are companies and candidates from all over the world. It is the best methods for passing exam.